Turbidity Sensor

 

 

The turbidity sensor uses a combination of transmission and 90° scattering in a flow-through system. The two photodetectors for scattered and transmitted light and the light source (IR-LED) are situated in a flow-through system made of stainless steel (V4A).

It can be used to determine the turbidity of fresh water and seawater or other liquids and is designed to be part of a flow-system that is optimised for water quality monitoring.

The sensor can be modified to the customer's needs regarding measuring range and accuracy. The response time is less than 5 seconds. The turbidity sensor provides the sensitivity, accuracy and long-term stability required for the continuous measurement of turbidity in estuaries and lagoons.

 
 

Item-Number

48 806 600 D0 A

Range

2 to 1000 FNU

Accuracy

3 % of the measured value

Response time

< 5 seconds

Resolution

1 FNU

Ambient temperature limit

Storage: -10°C to +45°C
Operation: - 4°C to +45°C

Power supply

24 VDC, 2 W

Dimensions (widthxheightxdepth)

200x127x80 mm

Weight

approx. 2100 g

Type of sensor/Measuring principle

nephelometric,
with infrared-LED

Protection class

IP 65

Interface

CAN-Bus
 
     
  Broschure download  