Left Arrow to previous page
Atex Certification Logo 3A Logo Certification
 

Diaphragm Metering Pump - NOVADOS H2

Bran+Luebbe’s unrivalled range of NOVADOS diaphragm metering pumps are ideal for practically every situation where liquids have to be metered and blended. NOVADOS diaphragm metering pumps include leakage-free diaphragm pumps and plunger pumps.

Electrical connection: 3ph; 230/400 V; 50/60 Hz; IP 55; ISO KL. F. Ambient temperature: -40°C up to +40°C, product temperature: 0°C at 100°C. Gear type: integrated worm gear; reduction ratios: 28:1, 28:2, 33:2, 39:2, 44:2 ; resulting stroke frequency depends on motor type and mains frequency; lubrication: splash.


Diaphragm Metering Pump - NOVADOS H2
Diaphragm Metering Pump - NOVADOS H2 - Drawing Open Diaphragm Metering Pump - NOVADOS H2 - Drawing Closed
Weight, according to equipment (without motor) approx. 70 - 155 kg

Diaphragm Metering Pump Options

Diaphragm Metering Pump General Specifications

Materials of Construction of Liquid-wetted Parts:

  • Housings of St. Steel 1.4571, 1.4581 or 1.4462, alternatively, PVC or PP
  • Diaphragms of PTFE or stainless steel 1.4310
  • Plungers of stainless steel or ceramic
  • Options: materials such as Super Duplex, Hastelloy, Titanium, Halar® coating or PVDF and other materials

Pump Gear Design:

  • Worm gear with a variety of five different reduction ratios
  • Integral housing utilizing modern seal technology
  • Splash lubricated gear components
  • Large oil sump
  • No external oil pump
  • Suitable for variable speed

Stroke Length Adjustment:

  • Eccentric (Z-shape) crankshaft

Flow Rate Control:

  • Manually, electrically, or pneumatically during operation and standstill

Driver:

  • 2- or 4-pole electric motor with fixed or variable speed

Applicable Standards:

  • API 675 2nd edition

CE-Marking:

  • 98/37/EC (Machinery Directive)
  • 94/9/EC (ATEX) up to category 2

Flow Rate and Pressure for Single Diaphragm Metering Pumps

Pumphead type

Diaphragm

Plunger

 

Nozzle Size

Material of displacement body
Housing material

PTFE
St. Steel / Plastic

St. Steel
St. Steel

Ceramic or St. Steel
St. Steel or Plastic

Flow rate at 200 min-1

max. operating pressure

l/h

GPM

bar 1)

PSI

bar 1)

PSI

bar 1)

PSI

 

0... 7,0

0.031

100

1450

700

10,153

500

7,252

8

0...10,1

0.044

-

-

500

7,252

500

7,252

4 or 8

0...18,1

0.08

250

3,626

298

4,322

298

4,322

8

0...28,2

0.124

315

4,569

315

4,569

315

4,569

8

0...40,7

0.179

221

3,205

221

3,205

221

3,205

8

0...72,4

0.319

124

1,798

-

-

124

1,798

6

0... 113

0.5

80

1,160

80

1,160

80

1,160

15

0... 177

0.779

51

740

51

740

51

740

15

0... 254

1.118

35

508

35

508

35

508

15

0... 366

1.610

24

348

-

-

24

348

15

0... 499

2.196

18

261

18

261

18

261

15

0... 707

3.111

13

189

-

-

13

189

25

0... 887

3.903

10

145

-

-

10

145

25

0...1087

4.783

8

116

-

-

8

116

25 / 40

0...1307

5.751

7

102

-

-

7

102

25 / 40

0...1590

6.996

6

87

-

-

6

87

25 / 40

Additional Informational Links:

General Information on NOVADOS H series Diaphragm Metering Pumps

Checklist for Metering and Process Pump Specification

Product Literature

Site Map | SPX Corporation | SPX Flow Technology