Diaphragm Metering Pump Options
Diaphragm Metering Pump General Specifications
Materials of Construction of Liquid-wetted Parts:
- Housings of St. Steel 1.4571, 1.4581 or 1.4462, alternatively, PVC or PP
- Diaphragms of PTFE or stainless steel 1.4310
- Plungers of stainless steel or ceramic
- Options: materials such as Super Duplex, Hastelloy, Titanium and other materials
Pump Gear Design:
- Worm gear with a variety of four different reduction ratios
- Forced feed/ splash lubricated gear components
- Large oil sump
- Suitable for variable speed
Stroke Length Adjustment:
- Eccentric (Z-shape) crankshaft
Flow Rate Control:
- Electrically, or pneumatically during operation and standstill
Driver:
- 4-, 6- or 8-pole electric motor with fixed or variable speed
Applicable Standards:
CE-Marking
- 98/37/EC (Machinery Directive)
- 94/9/EC (ATEX) up to category 2
Flow Rate and Pressure for Single Diaphragm Metering Pumps
Pumphead type |
Diaphragm |
Material of displacement body
Housing material |
PTFE
St. Steel / Plastic |
Flow rate at 167 min-1
|
Max. operating pressure
|
l/h |
GPM |
bar 1) |
PSI |
0... 1223 |
5.382 |
- |
- |
0...1664 |
7.322 |
400 |
5,802 |
0...2359 |
10.38 |
400 |
5,802 |
0...2959 |
13.02 |
400 |
5,802 |
0..3.627 |
15.959 |
350 |
5,076 |
0...4363 |
19.197 |
250 |
3,626 |
0...7643 |
33.629 |
160 |
2,321 |
0...9435 |
41.514 |
125 |
1,812 |
0... 12000 1) |
52.8 |
80 |
1,160 |
1)Stroking speed 136m-1
Additional Informational Links:
General Information on NOVADOS H series
Checklist
for Metering and Process Pump Specification
Product Literature
|